What is ICRU ?
ICRU stands for International Commission on Radiation Units and Measurements. it has principal objective on the development of internationally acceptable recommendations regarding :
- Quantities and units of radiation and radioactivity.
- Procedures that is suitable for the measurements and applications of these quantities in clinical radiology and radiobiology.
- physical data needed in the application of these procedures, the use of which tends to assure uniformity in reporting.
source : google |
ICRU 83
ICRU 83 : Prescribing, Recording and Reporting Photon-Beam Intensity-Modulated Radiation Therapy (IMRT)
This ICRU Report are closely related to the previous ICRU Reports 50, 62,71 &78.
It emphasize on :
source : google |
This ICRU Report are closely related to the previous ICRU Reports 50, 62,71 &78.
It emphasize on :
- Gross Tumour Volume (GTV)
- Clinical Target Volume (CTV)
- Planning Target Volume (PTV)
- Organ at Risk (OAR)
- Planning organ-at-risk Volume (PRV)
- Internal Target Volume (ITV)
- Treated Volume (TV)
- Remaining Volume at Risk (RVR)
As a summary, this report discusses on :
- For malignant tumour, CTV should always be associated with the GTV .
- the use of dose-volume histograms(DVHs) for the specification of absorbed dose is inherent to the treatment modality
- Describes optimization techniques, which can control the compromise of absorbed-dose homogeneity in the PTV with dose reduction in the PRV.
- Designate the sets of treatment goals as the "planning aims" to differentiate them from the "prescription" .
- Recommendations concerning absorbed-dose reporting evolve from previous ICRU recommendations while attempting to retain a relationship with the previous recommendations.
- Recommends that the median absorbed dose, specified by D50% should be reported as it is considered to correspond best with the previously defined dose at the ICRU references point.
- Recommends that in low gradient situation , define as a relative change of absorbed dose that is less than 20% per cm in any direction, that 85% of target volume absorbed dose samples should be within 5%
More info on ICRU , U can visit this link below :